Page 2: ...0 Installation and Configuration Guide II Corning MobileAccess 8391 Old Courthouse Road Suite 300 Vienna VA 22182 Tel 1 866 436 9266 1 703 848 0200 TAC 1 800 787 1266 Fax 1 703 848 0280 www corning com mobileaccess ...

Page 3: ...Repair MOBILEACCESS TESTS AND INSPECTS ALL ITS PRODUCTS TO VERIFY THEIR QUALITY AND RELIABILITY MOBILEACCESS USES EVERY REASONABLE PRECAUTION TO ENSURE THAT EACH UNIT MEETS THEIR DECLARED SPECIFICATIONS BEFORE SHIPMENT CUSTOMERS SHOULD ADVISE THEIR INCOMING INSPECTION ASSEMBLY AND TEST PERSONNEL ABOUT THE PRECAUTIONS REQUIRED IN HANDLING AND TESTING OUR PRODUCTS MANY OF THESE PRECAUTIONS CAN BE FO...

Page 4: ...IES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE MOBILEACCESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING BUT NOT LIMITED TO INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS PARTS AND SERVICE HEREUNDER OR THE PERFORMANCE USE OF OR INABILITY TO USE THE GOODS PARTS AND SERVICE Reporting Defects THE UNITS WERE INSPECTED BEFORE SHIPME...

Page 5: ...CES AND THE ASSOCIATED CABLES MOBILEACCESS2000 COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO 50 2007 MOBILEACCESS2000 EMPLOYS A CLASS 3B LASER AND THEREFORE THE FOLLOWING LABEL IS AFFIXED INSIDE THE UNIT ADJACENT TO THE LASER THE PRODUCT ITSELF HAS BEEN TESTED AND CERTIFIED AS A CLASS 1 LASER PRODUCT TO IEC EN 60825 1 2007 IT ALSO MEETS THE REQUIREMENTS...

Page 6: ...n MobileAccess products have met the approvals of the following certifying organizations Product Certifications US FCC 47 CFR part 15B 22 24 90 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation ...

Page 7: ...r manuals see Additional Relevant Documentation below Additional Relevant Documents The following documents are required if the corresponding units are included in your system Document Name MA850 MA860 Installation and Configuration Guide MobileAccess2000 700 800 Public Safety RHU Quick Installation Sheet MobileAccess1000 MobileAccess2000 User Manual Addendum for 700 MHz LTE Solution RIU Installat...

Page 8: ...Preface MA2000 Installation and Configuration Guide VIII DL Downlink RU Remote Hub Unit RIU Radio Interface Unit UL Uplink ...

Page 9: ...VII Table of Contents IX 1 Introduction to the MA2000 System 1 1 1 MobileAccess2000 System Architecture 3 1 1 1 Head End Equipment 3 1 1 2 Remote End Equipment 3 1 2 Application Examples 5 2 MA2000 System Elements 8 2 1 Enclosure Types 9 2 1 1 MA2000 Remote Cabinet 9 2 1 2 MA2000 Lite 11 2 1 2 1 Enclosure Internal Elements 12 2 1 2 2 Digital Card Unit 13 2 1 2 3 Filters and Combiners 13 2 1 3 MA20...

Page 10: ...r Safety Instructions 26 3 5 2 Power Consumption of Units 26 3 5 3 Circuit Breakers 26 3 5 4 Types of Power Supplies 27 3 6 Installation Conventions 27 4 System Installation 29 4 1 Pre installation Instructions 29 4 1 1 Unpacking and Inspection 29 4 2 Communication Room Installation 29 4 2 1 Rack Installation General Instructions 30 4 2 2 Rack Installation Safety Instructions 31 4 2 3 BU Connectio...

Page 11: ...Typical International Configurations 50 5 4 1 Typical Asian Configuration Cell DCS UMTS 50 5 4 2 Typical European Middle East Configuration EGSM DCS UMTS Configuration 50 5 4 3 iDEN 50 5 5 MA2000 Lite Cell DCS and GSM DCS Config for Telstra 51 6 Appendix System Specifications 52 RF Parameters 52 System Specs 56 Specifications of Units 57 6 1 1 MA 2000 MRC Remote Hub 57 6 1 2 MA 2000 Lite 57 6 1 3 ...

Page 12: ... MA2000 Cabinet MRC internally houses a total of five remote units and MA1200 add on units with which MA850 MA860 can be integrated as an external assembly NOTE MA2000 QSX unit is identical to the MA2000 TSX unit in addition to an Add on service mounted on top of the enclosure Figure 1 1 MA2000 Lite left side and MA2000 Cabinet right side The supported units are Remote Units RUs Service specific m...

Page 13: ...pacity All active components are located in the communication closet room Carrier class operation MA2000 advanced signal handling ensures optimal performance for all services within a multi operator deployment Local and remote end to end monitoring and control through interface to SC 450 controller Conditioning and monitoring of input RF signals at the head end through interface to MA RIU ...

Page 14: ...they are converted back from RF optical to RF electrical before being passed on to the RIU System Controller The system controller enables centralized remote management and control of all MobileAccess2000 elements 1 1 2 Remote End Equipment At the remote end the optical signal is reconverted to RF amplified filtered and distributed over the broadband antenna infrastructure Service Combiner Unit SC...

Page 15: ...Each pre configured RHU supports up to two services Add On Module AO The AO is a single service module coupled with an RHU to deliver an additional third service at a lower incremental cost The AO receives RF signal from the RHU and amplifies it for transport across the broadband coax For end to end control controllers installed at the head end provide direct interface to the MA elements and throu...

Page 16: ...ta services if MA850 MA860 units are installed and distribute them over the coax antenna infrastructure The MA SC 450 in installations with remote management provides monitoring and control of all active system elements Application Examples Figure 14 shows an example of an MA2000 Cabinet based solution Five services from two different operators are distributed where services from Operator A confli...

Page 17: ...Introduction to the MA2000 System MobileAccess2000 TSX System Architecture MA2000 Installation and Configuration Guide 6 Figure 1 3 Example of MA2000 Cabinet Architecture ...

Page 18: ...ces from two different operators are distributed The converted optical signal is routed from the BUs directly to the corresponding RUs over optic fiber Services 1 and 2 are distributed through one of the RUs supported by MA2000 Lite Services 3 and 4 are distributed through the second RU The combiner and filter provides interface to the antennas Figure 1 4 Example of MA2000 Lite Architecture ...

Page 19: ...ndividual connections The element descriptions are organized according to the following sections Enclosures typesLite Remote Location Elements MA2000 Remote Units RUs MA1200 Add on Base Unit NOTE The following elements are fully described in their corresponding user guides MA RIU MA 850 MA860 SC 450 Controller MCT NMS Management Application described in MA410 MA430 Installation and Configuration G...

Page 20: ...hat can be housed depends on the models required filtering etc MA850 MA860 can be connected externally Converges all voice services and provides a single interface to the antennas through external connections Wall mounted or rack mounted Supplied in two models with differing power supply Integrated power supply fed from an external AC power source The MA2000 RHU an MA1200 Add on modules are intern...

Page 21: ... to the relevant filters and to the 8x4 Combiner The PS connections of each module are also connected to cables that are internally routed to the integrated PS a full detailed description of the connections is provided in chapter 5 NOTE The fiber optic connections are not displayed Figure 2 3 MA2000 MRC Open Cabinet with Internal Cabling Optic fiber connection from the corresponding BU Slot for fi...

Page 22: ...er supplies The MA2000 enclosure contains two sets of cables each providing connections to two MA2000 RUs Cable Connector Description Four N type connectors Coax connections to corresponding antennas 1x DB 9 connector Connection to RU front panel RS232 connector The following table describes the MA2000 Lite front panel connectors Connector Description Ant 1 to Ant 4 N type Coax connections to corr...

Page 23: ... Module is operating properly Power Green required power is supplied 2 1 1 1 Enclosure Internal Elements The MA2000 Lite enclosure includes 8x4 Combiner see section 2 2 3 for description Digital Card unit see 2 1 2 2 Filters and Combiners see 2 1 2 3 Figure 2 5 MA2000 Lite Internal Units Digital module Rear tab 8x4 Combiner Filters and combiners Front tabs ...

Page 24: ...Lite enclosure front panel Digital Unit Rear Panel The rear panel of the unit contains the control connections to the 8x4 Unit and to the Remote Units Figure 2 7 Digital Rear Panel 2 1 1 3 Filters and Combiners The filters and combiners vary according to the type of Remote Units The filter and combiner connections are described in Chapter 5 Upgrading and Configuration Examples MA2000 TSX supports ...

Page 25: ...MA2000 TSX Open Cabinet View The antenna ports of the individual modules are connected to the relevant filters and to the 8x4 Combiner The PS connections of each module are also connected to cables that are internally routed to the integrated PS a full detailed description of the connections is provided in chapter 5 NOTE The fiber optic connections are not displayed Also the antenna connections ar...

Page 26: ...U to which it is connected MA850 MA860 converges data services from 802 11a b g APs and distributes them over the same coax and antenna infrastructure NOTE The MA850 MA860 is described in detail in the MA850 MA860 Configuration and Installation guide 2 2 1 MA2000 RU MA2000 RU is a service specific module that is either housed in the MA2000 Cabinet or connected externally to the MA2000 Lite module ...

Page 27: ...c connections to the BU four coax connections to the antennas power connections and status indicators Figure 2 9 MA2000 RU Front Panel Table 2 1 RU 2000 Front Panel Indicators LED Description COMM Active communication detected LINK Optical link to BU detected PWR DC power connection 20 to 48VDC Fiber optic BU connections Power connector LEDs MA service connecto RF ports 1 to 4 ...

Page 28: ...cting to an MA1200 Add On unit Figure 2 10 MA2000 RU Rear Table 2 2 MA2000 RU Rear Panel Connectors Add on control Transmits the control signals from MA1200 Add On module to the MA2000 RU module The Add on Control port is connected to the MA1200 Add On From port DL UL Transmit the RF signals to and from the MA1200 Add On module These ports are connected to the corresponding ports on the MA1200 rea...

Page 29: ... infrastructure does not perform the optic to RF conversion and does not interface to the antennas All these functions are provided by the host MA2000 RU unit 2 2 3 1 MA1200 Front Panel The MA1200 front panel contains the power connection and status LEDs The RS 232 connector is reserved for MA service personnel The figure below shows the MA 1200 front view It is followed by a description of the co...

Page 30: ...he MA1200 add on module These ports are connected to the corresponding ports on the MA 2000 rear panel DL to DL UL to UL High Service RF output port Connected to combiner splitter to be combined with other services supported by the MA2000 system 2 2 4 8 x 4 Combiner NOTE This unit is internal to the MA2000 system both Cabinet and Lite models This unit is installed in the MA2000 system Cabinet and ...

Page 31: ...orts as well as the control port Figure 2 14 8x4 Combiner Rear Panel The following table describes the rear panel connectors NOTE Connector on rear panel is for future option SMA Connectors Description Low Band Four connectors ports 1 4 for the low band outputs of the corresponding remote unit Refer to Chapter 5 for the exact connections relevant to each configuration High Band Four connectors por...

Page 32: ... Unit Models and OPTMs Two models of MA BUs are available Four port unit supports optic connections to four RUs Eight port unit supports optic connections to eight RUs Each 4 port unit is referred to as OPTM An 8 port unit consists of two 4 port modules or referred to as OPTMs NOTE Each 4 port module OPTM is separately accessed and managed in the MCT and NMS management applications 2 3 2 BU Panels...

Page 33: ...s the rear panel of an 8 port BU A 4 port BU contains a single UL and a single DL RF connector Figure 2 17 MA BU Rear Panel RF Connections Table 2 7 MA BU Rear Panel Connections Connector Description Uplink output Uplink connectors to be connected on BTS BDA side For an 8 port BU both UL connectors must be connected Downlink input Downlink connectors to be connected on the BTS BDA side For an 8 po...

Page 34: ...evant to the specific installation 3 3 Coaxial Cable Connections 3 3 1 General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area The building code requires that all cabling be installed above ceiling level where applicable The length of cable from the risers to each antenna must be concealed above the ceiling The cable mu...

Page 35: ...ior to terminating the RUs in the remote communication rooms Terminate all unused RU and RIU ports with a 50 ohm load 3 3 3 Coax Cable Lengths and Losses Use coax 50ohm male to male N type for connecting to RHU and antenna ports NOTE The required distance between the antennas installed in the ceiling depends on the infrastructure and calculated path loss For example if there is free space loss bet...

Page 36: ...0 2000 4500 micron Diamond p n ENC 1045342 Black Brown boots 1 Meter MA 50000105 Diamond p n ENC 1045343 Black Brown boots 3 Meter MA 500001060 Zipcord patchcord 4xSC APC 62 5 125 900 2000 4500 micron Diamond p n ENC 1045344 Beige Brown boots 1 Meter MA 500001061 Diamond p n ENC 1045345 Beige Brown boots 3 Meter MA 500001062 Use only 8 degree SC APC connectors green color Use only fusion splice fo...

Page 37: ...onfiguration Use only UL approved power supplies AC and DC power supply cables only use the power cords supplied with the units Battery replacement in units only the SC 450 controller has batteries These should be replaced when necessary only by MA Service Personnel Install external over current protective devices for the system according to the requirements described in section 3 5 2 3 5 2 Power ...

Page 38: ...oncentrated in the same location most often in the main communication room Remote Cabinet Lite usually placed in the communication shaft or closet of a corresponding floor so they can be easily located Each cabinet or MA2000 Lite can typically cover a floor of up to 30 000 sq ft Fiber optic cable bundled fibers are terminated into the Base Units in the main communication room The fibers are then r...

Page 39: ...roviding power from a single distribution point maintenance can be reduced and UPS backup can be easily provided The maximum distance from the source to the termination spot is 1000 feet using 18 gauge wires In many locations local codes do not require power to be run through conduit if 100 watts or less is used Please consult the regulations in your local jurisdiction prior to deploying remote po...

Page 40: ...opologies are described in detail for single building and for multi building By understanding the two generic installations you will be able to address any variations in system deployment NOTE For installations that include the MA NMS Once the installation has been completed it can be verified using the MCT application NMS User s Guide and the devices monitored using the NMS Manager NMS User s Gui...

Page 41: ...oller 1U Fiber Optic patch panel and splice tray Power supply supplies MobileAccess 3U for each unit units from other manufacturers may vary in size Verify that the rack height can support all the units to be installed where you may also want to consider future expansions Figure 41 shows the recommended physical location of the MobileAccess elements in the rack in order to facilitate and simplify ...

Page 42: ...d personnel should be allowed to install or replace this equipment Verify that ambient temperature of the environment does not exceed 50 C 122 F To maintain a low center of gravity ensure that heavier equipment is installed near the bottom of the rack and load the rack from the bottom to the top Ensure that adequate airflow and ventilation within the rack and around the installed components so tha...

Page 43: ...d in the rack near the BUs To connect the BU 1 Connect fiber jumper between splice tray and patch panel cabinet 2 Connect fiber jumpers between the corresponding BU optical ports and the patch panel Figure 4 2 BU Front Panel Connections 3 Connect the BU rear panel Uplink and Downlink ports to the corresponding ports on the RIU rear panel or to the RF ports from the passive interface if your system...

Page 44: ...rocedures NOTE For installations that include MA850 MA860 units refer to the MA850 MA860 Installation and Configuration Guide for instructions on various installation options with the MA2000 General Installation Instructions The MA2000 Remote Cabinet units should be installed in a communication room that provides access to authorized personnel only The units are maintenance free In the event of fa...

Page 45: ...on the wall and a bracket that is assembled on the rear of the MA2000 system Figure 4 5 MA2000 System Wall Mount Figure 4 6 Zoom of Mounting Holes Plate to be mounted on the wall Mounting Bracket Location of anchors Opening through which connected optic fibers are routed Underside opening through which power connections are routed Rear panel bracket Holes for plate to bracket assembly ...

Page 46: ...ptional connect the cabinet GND according to section 4 3 2 2 Using the plate as a guide drill four holes for concrete anchors Insert four concrete anchors McMaster Carr catalogue number 92403A200 or equivalent 3 Mount the Plate on the wall Carefully and thoroughly fasten the anchors to the wall 4 Assemble the Bracket onto the rear of the Remote Cabinet using the supplied screws 5 Lift the MA2000 M...

Page 47: ... 3 2 MRC Grounding Integrated PS Wall Mount Model NOTE This procedure is only necessary for wall mount integrated power supply configuration for other configurations this procedure is optional The Ground screw is located at the rear of the unit Figure 4 7 Grounding Located at the Rear of the Unit ...

Page 48: ...Rack Mount Installation NOTE The cabinet requires a clearance of 10 cm above the unit If a heating source is installed beneath the MRC a buffer must be placed between the cabinet and the surface The following figure provides the dimensions for the MA2000 Rack Model Figure 4 8 MA2000 Cabinet Rack Mount Assembly ...

Page 49: ...8 The MA2000 MRC Rack Mount model is supplied with the required brackets already assembled to the sides of the cabinet as illustrated in the Figure 49 MA2000 MRC Rack Model Simply mount the MA2000 MRC in the rack and secure with the supplied screws Figure 4 9 MA2000 MRC Rack Model Rack brackets ...

Page 50: ... to each RU 2000 module 3 For the downlink connect the fiber optic cable pigtails from splice box coming from the BU port to the corresponding RU port routing the optic fibers so they will fit through the top opening in the door 4 For the uplink connect the fiber optic cable pigtails from splice box from the RU routing the optic fibers so they will fit through the top opening in the door to the up...

Page 51: ...ou may also connect a backup battery of 48V to the battery connector This is an optional connection Figure 4 11 Partial View of system illustrating location of power connections 4 3 5 2 External Power Supplies Model The external power source may be a central source with cables routed to each RU or RU dedicated power supplies locally installed PS 24 VDC to 48 VDC Connect each power connection to th...

Page 52: ...munication shaft of the corresponding floor The remote units are mounted externally to the MA2000 Lite device and their antenna outputs are connected to either side of the MA2000 Lite device The combined outputs are then connected to the antennas in the covered area The following figure illustrates MA2000 Lite connections to two RUs Figure 4 12 MA2000 Lite System Coax Connections MA2000 Lite enclo...

Page 53: ...m Installation MA2000 Lite Installation and Connections MA2000 Installation and Configuration Guide 42 The following figure shows the RIU Lite mechanical drawing Figure 4 13 MA2000 Lite Mechanical Dimensions ...

Page 54: ... displayed The installed filters vary depending on the RU models in the installation Figure 4 14 MA2000 Lite Prepared for Mounting 2 Depending on the tools you use Either measure the distance between the four wall mount holes and drill the required holes in the wall and insert the screws or Hold the tray up against the wall and simply drill the screws in the holes 3 Mount each MA2000 RU on the wal...

Page 55: ... 1 Connect the antenna cables to the front panel antenna connectors 2 Connect the DC power 3 Connect each of the side cable N type antenna connectors to the antenna connectors of the corresponding RU 4 Connect each of the side cable D type connector to the front panel RS232 connectors of the corresponding RU Connections to MA2000 RU front panel RS232 and antenna connectors 1 To Antennas 2 Power LE...

Page 56: ...etc to the 8x4 Module and to the external coax infrastructure NOTE It is required to order an Accessory Kit for each new unit to be added to the installation The kit includes cables for connecting the MA2000 RU or MA1200 Add On units to the required filters Because of the differences in cable length requirements the accessory kit differs for units designated to be installed in 2000 Cabinets and fo...

Page 57: ...and SMR coverage is implemented by one remote unit This type of configuration was designed to meet Nextel s existing needs MA1200 add on module for PCS support can be integrated into the solution at any time in order to meet future needs The following figure describes the port connections between the remote units add on and 8x4 Combiner Figure 5 1 iDEN SMR and PCS Connections ...

Page 58: ...llowing figure Figure 5 2 Single Cell PCS Connections For infrastructures supporting two Cell bands and a PCS band connect the second Cell PCS services RU according to the following figure Figure 5 3 Additional Cell PCS Connections P1 P4 P3 P2 RHU 2000 CELL PCS Cavity Cell Duplexer N C 8x4 P1 8x4 P5 Cavity Cell DL Tx Rx Com P1 P4 P3 P2 RHU 2000 CELL PCS Cavity Cell Duplexer N C 8x4 P4 8x4 P8 Cavit...

Page 59: ...ovides a description of how to connect up to three Cell PCSH services Note In cases requiring more than one RHU connect the additional units according to 2nd and 3rd RHU configuration 5 1 3 1 Cell PCSH and LTE 700 The following figure shows the connections for a configuration consisting of a 700 LTE Add On unit with external filter and Cell PCSh RHU ...

Page 60: ...it 5 3 Public Safety 700 800 NOTE Both the MA2000 Public Safety 700 800 RHU and the corresponding filter unit are installed EXTERNALLY on the Cabinet For information on the installing and configuring the MA2000 Public Safety 700 800 RHU refer to the MobileAccess2000 700 800 Public Safety RHU Quick Installation Sheet provided with the unit The installation connections are as follows Figure 5 4 700 ...

Page 61: ...te supports Cell DCS and DCS UMTS support can be added through MA1200 Add On 5 4 1 Typical Asian Configuration Cell DCS UMTS Figure 5 5 Cell DCS and UMTS Configuration 5 4 2 Typical European Middle East Configuration EGSM DCS UMTS Configuration Figure 5 6 Typical European Middle East Configuration 5 4 3 iDEN iDEN support is provided through MA2000 Cabinet configurations ...

Page 62: ...2000 Lite Cell DCS and GSM DCS Config for Telstra MA2000 Installation and Configuration Guide 51 5 7 iDEN Configuration 5 5 MA2000 Lite Cell DCS and GSM DCS Config for Telstra RHU 2000 iDEN P1 P2 P3 P4 Cavity iDEN DL BPF to 8x4 P6 to 8x4 P2 ...

Page 63: ...ti io on ns s RF Parameters RF Frequency Range Services Frequency Range Uplink Downlink CELL 824 849 869 894 iDEN 806 824 851 869 GSM 890 915 935 960 E GSM 880 915 925 960 Telstra 850M 824 849 869 890 SMR 896 902 929 941 DCS 1710 1785 1805 1880 PCS 1850 1910 1930 1990 G PCS 1850 1915 1930 1995 UMTS 2100 1920 1980 2110 2170 ...

Page 64: ...U D U D U D U Max output PWR per antenna port 1 comp 16 14 10 12 14 10 2 carriers 13 11 7 9 11 7 4 carriers 10 8 4 6 8 4 8 carriers 7 5 1 3 5 1 12 carriers 5 3 1 1 3 1 Mean Gain dB 16 7 14 7 10 7 12 7 14 7 10 7 Pin dBm 0 0 0 0 0 0 Input IP3 dBm AGC OFF Min 5 5 5 5 5 5 Input IP3 dBm AGC ON Min 5 5 5 5 5 5 SFDR dB 71 72 72 64 71 71 Max Intermod Distortion dBm 13 13 13 36 13 13 Max Nf dB 20 20 20 20 ...

Page 65: ...calculated in 100Kb sec RF Parameters High Band RU 2000 DCS PCS CDMA WCDMA PCS GSM TDMA D U D U D U Max output PWR per antenna port 1 comp 14 14 16 2 carriers 11 11 13 4 carriers 8 9 10 8 carriers 5 6 7 12 carriers 3 4 5 Mean Gain dB 14 3 14 3 14 3 Pin dBm 0 0 2 Input IP3 dBm AGC OFF Min 6 6 6 Input IP3 dBm AGC ON Min 3 3 3 SFDR dB 64 66 64 Max Intermod Distortion dBm 30 13 13 Max Nf dB 20 20 20 G...

Page 66: ... 14 15 15 8 carriers 11 12 12 12 carriers 9 10 10 Mean Gain dB 20 3 20 3 21 3 Pin dBm 0 1 0 Input IP3 dBm AGC OFF Min 7 7 7 Input IP3 dBm AGC ON Min 3 3 SFDR dB 66 64 66 70 Max Intermod Distortion dBm 13 13 Max Nf dB 20 20 20 Gain Flatn dB 2 0 Factory set mean gain BU RHU without RIU May be field adjusted using system controller SFDR for CDMA services is calculated in 100Kb sec UMTS Compiles with ...

Page 67: ... 3 dB total Optical loss per mated pair connectors 0 5dB max Optical Connector SC APC Fiber type 9 125 SM Wavelength 1310 10nm Maximum distance between Base Unit and Remote Cabinet 2Km Absolute Maximum Rating Total Input RF Power to BU 10dBm Total Input RF Power to RU 20dBm out of band 10dBm in band Power Supply VDC 60VDC Temperature Specifications Operating 0 C to 50 C 32 F to 122 F Storage 20 C ...

Page 68: ...ctions to two Remote Units MA 1200 Add ons each unit RF antenna connections Four N type female antenna connections Power consumption 3W max housing only with no remote units Physical Mounting Wallmount Dimensions 442 x 336 x 86 41mm 17 4 x 13 23 x 3 4 Weight 5 5Kg 12 1lb 6 1 3 MA 2000 Remote Unit Supported services Two services corresponding to the model Power Input power 20 to 48V DC Power consum...

Page 69: ...dated ordering information Remote HUBs 2000 RC RP 2000 RC LP 2000 MINI ENC Remote Cabinet all services Remote powering Remote Cabinet all services Local powering 2000 enclosure supporting 2 modules Dual Band RF Modules add on ready MA2000 Cabinet 2000 CELL DCSE 2000 CELL PCSE 2000 GSMO DCSE 2000 IDEN SMR 2000 E GSM DCS Dual band Cell DCS 1 port for cabinet enhanced power Dual band Cell PCS 1 port ...

Page 70: ...r cabinet Add on RHU PCS service for Lite Add on RHU UMTS service for Lite MobileAccess Universal Base Units WB B8U WB B4U Wide Band Base 8 Unit supporting 8 RHUs Wide Band Base 4 Unit supporting 4 RHUs Network Controller SC 450 Network Controller Ethernet IP Interface 410 430 Network Controller Serial Interface dial up Network Controller Ethernet IP Interface Network Management System NMS SW SERV...

Page 71: ...r PCS w G Block support BTS Conditioner for SMR Paging BTS Conditioner for GSM 900MHz BTS Conditioner for EGSM 900MHz BTS Conditioner for DCS 1800MHz BTS Conditioner for UMTS 2100MHz BDA Conditioner for Cellular BDA Conditioner for iDEN BDA Conditioner for PCS BDA Conditioner for PCS w G Block support BDA Conditioner for SMR Paging RIU Lite for iDEN800 SMR 900 PCS1900 w G Block support 1BU8 RIU L ...

Page 72: ...61 MA2000 Installation and Configuration Guide This page is intentionally left blank ...

Reviews: