![background image](http://html1.mh-extra.com/html/omron/sysmac-c1000h/sysmac-c1000h_operation-manual_743079231.webp)
225
Address
Instruction
Operands
Address
Instruction
Operands
00000
LD
00000
00001
AND
25204
00002
AND NOT
12802
00003
LD
12801
00004
KEEP(11)
12800
00005
LD
12800
00006
@MOV(21)
#
000A
DM
0000
00007
@MOV(21)
#
0000
DM
0001
00008
@MOV(21)
#
0003
DM
00002
00009
@XFER(70)
#
0010
000
DM
0002
00010
@SEND(90)
DM
0010
DM
0020
DM
0000
00011
LD
12800
00012
AND
25203
00013
OUT
00200
00014
LD
12800
00015
AND
25204
00016
DIFU(13)
12801
00017
LD
00001
00018
AND
25204
00019
AND NOT
12800
00020
LD
12803
00021
KEEP(11)
12802
00022
LD
12802
00023
AND
25204
00024
AND NOT
25203
00025
XFER(70)
#
0016
000
DM
0030
00026
LD
12802
00027
@MOV(21)
#
0010
DM
0003
00028
@MOV(21)
#
0000
DM
0004
00029
@MOV(21)
#
007E
DM
0005
00030
@RECV(98)
HR
10
LR
10
DM
0003
00031
LD
12802
00032
AND
25203
00033
OUT
00201
00034
LD
12802
00035
AND
25204
00036
DIFU(13)
12803
Network Instructions