250
Example
Previously set stop address
Start address
Previously set trigger address
Previously set delay
Use the NOT key to
switch b and –.
Indicates number of execution
loops when trigger address is
not found before the stop
address or END(01) instruction.
Program address being executed
Aborting while tracing is in progress
When tracing finishes, the dis-
play returns to as it was before
(with the final address).
00000RUN ?
STOP ADRS 02121
00000RUN ?
TRIG ADRS 00000
00000RUN ?
TRIG ADRS 01000
00000RUN ?
DELAY -000
00000RUN
DELAY -211
****** RUN G
****
00000<DEBUG>
00000 STEP? 0
LD 00000
00000RUN ?
STOP ADRS 00000
00000 STEP? 0
LD 00000
00800 RUN HALTED
OUT 01005
If no trigger address is found between address 00000 and either the stop ad-
dress or END(01), no tracing will occur and execution will loop for 250 ad-
dresses.
7-1-6
Address Trace Read
The Address Trace Read operation is used to read the contents of Trace
Memory starting with the trigger address. Pressing the up and down keys
increments or decrements the Trace Memory area address being read.
Debugging
Section 7-1