236
Notes
1.
The execution time is given in microseconds unless otherwise stated.
2.
Times for non-differentiated forms are given to the left of the slash, and those for differentiated forms given to the right.
Instruction
OFF execution time (
µ
s)
1,2
ON execution time (
µ
s)
1,2
Conditions
C2000H
C1000H
C2000H
C1000H
TIM
Constant for SV
2.4
2.4
R:
2.4
IL:
2.4
JMP:
2.4
*
DM for SV
20
13
R: 29
IL: 29
JMP: 14
R: 19
IL: 19
JMP: 10
CNT
Constant for SV
2.4
2.4
R:
2.4
IL:
2.4
JMP:
2.4
*
DM for SV
16
11
R: 28
IL: 11
JMP: 11
R: 18
IL: 7
JMP: 7
NOP(00)
---
0.4
0.4
---
---
END(01)
---
8
5
---
---
IL(02)
---
9
6
8
6
ILC(03)
---
9
6
7
5
JMP(04)
---
10
7
9
6
JME(05)
---
10
7
9
6
FAL(06)
---
16/17
11/12
7/8
5/6
FAL(06) 00
---
11/12
7/8
7/8
5/6
FALS(07)
---
11/12
7/8
7
5
STEP(08)
---
24
16
15
10
SNXT(09)
---
10
6
7
5
SFT(10)
With 1-word shift register
40
26
R: 35
IL: 7
JMP: 7
R: 25
IL: 5
JMP: 5
With 252-word shift register
444
296
R: 20
0
IL: 7
JMP: 7
R: 13
3
IL: 5
JMP: 5
KEEP(11)
---
0.8
0.8
---
---
CNTR(12)
Constant for SV
21
14
R: 15
IL: 10
R: 10
IL: 7
*
DM for SV
29
19
JMP: 10
JMP: 7
DIFU(13)
---
16
10
Normal: 15
IL: 16
JMP: 8
Normal: 10
IL: 10
JMP: 5
DIFD(14)
---
16
11
Normal: 16
IL: 16
JMP: 9
Normal: 11
IL: 11
JMP: 6
Instruction Execution Times