What can be done by the setting tool
• Floating Blanking Mode
Floating blanking has the following 2 modes.
1. Sequential Beam Mode
2. Non-Sequential Beam Mode
1. Sequential Beam Mode
If a size of an interrupting object is specified size or smaller, safety output is not turned OFF.
But if interrupting object(s) enter more than one zone of detection zone, safety output is turned OFF.
Under this mode, floating blanking monitoring can be configured. (It cannot be if number of floating
beams is 1)
For minimum detection capability, see “Detection Capability”.
For a size of an object which should not be detected, see “Floating Beam”.
- Floating Blanking Function p.70
- Detection Capability p.77
- Floating Beam p.71
Number of Floating Beams
Number of Allowable Beams
1
Setting not possible
2
Only 1
3
1, 2
4
1, 2, 3