106
Ch
apt
e
r
3
Maint
e
na
nce
Inf
o
rma
tion
F3SJ-A
User’s Manual
What can be done by the setting tool
Maintenance Information
Error History
Overview
Details of errors that occurred in the past are displayed.
Functional Description
The PC tool for F3SJ can display the past 20 error codes, and the setting console can display the past
10 error codes.The PC setting tool for F3SJ can record error codes as well as F3SJ's internal
temperature, which can be displayed too. For an explanation of the error codes, refer to the
troubleshooting section at the end of this manual.
Monitor Items
Configure for each CH in case of a series connection.
- When the setting tool is connected while power is being supplied to the F3SJ, the F3SJ enters communication error
lockout. When checking errors in the error log, ignore the error that occurred most recently and check the second or
earlier errors.
- When an error occurred, a supply voltage error may be recorded in addition to the original error code if supply voltage
is out of specification range.
Power-on Time
Overview
The power-on time of the F3SJ is displayed.
Functional Description
Data related to the power-on time of the F3SJ is recorded in the F3SJ main unit every 15 minutes. The
record is made when in normal operation or during lockout. By knowing the power-on time, you can
better understand when to schedule F3SJ maintenance.
• Power-on time
This is the current power-on time since the power-on time was last reset. If the power-on time has
never been reset, this value is the same as the accumulated power-on time. This value can be
checked for an emitter and a receiver separately.
• Power-on time threshold value
When the power-on time exceeds this value, output can be performed to the auxiliary output or the
external indicator output.
Note that the power-on time information must be assigned to an output mode.
(In the initial settings, it is assigned to auxiliary output 2.)
- Auxiliary Output (Non-Safety Output) p.95
- External Indicator Output (Non-Safety Output) p.99
Function
Setting Console
PC Tool For F3SJ
Error history