63
F3SJ-A
User’s Manual
Ch
apt
e
r
3
F3SJ
St
at
us
When
Set
ting
T
ool Is
Conne
ct
ed
What can be done by the setting tool
E
F3SJ Status When Setting Tool Is Connected
Maintenance Status
Connecting setting tool turns F3SJ into maintenance status, allowing change of setting, operation
monitoring, and check of maintenance information.
Under the maintenance status, F3SJ operates as shown below:
•Safety output keeps OFF status.
•Indication statuses of internal indicator ON/OFF are partly different.(See below)
•Lockout does not occur except for model error, communications error, setting value error, or internal
circuit failure.
(For example, lockout does not occur even if a fixed blanking beam receives light)
Internal Indicators During Maintenance Status
When in the maintenance status, the emitter-side POWER indicator [POWER] and the receiver-side
ON or OFF indicator ([ON] or [OFF]) blink.
If the F3SJ is ON during normal operation, the ON output indicator blinks in the maintenance status.
The safety output is OFF.
If the F3SJ is OFF during normal operation, the OFF output indicator blinks and the safety output is
OFF in the maintenance status.
Apparent output is ON
(Safety output is OFF)
Apparent output is OFF
(Safety output is OFF)
Emitter
Receiver
Emitter
Receiver
Blinking
OFF
ON, blinking, or OFF,
depending on settings
PO WER
INTLK
EDM
B LA N KIN G
(TEST)
O N
O FF
PO WER
INTLK
EDM
B LA N KIN G
(TEST)
O N
O FF