160
Chapter
4
Wiring
F3SJ-A
User’s Manual
Wiring/Installation
Wiring Procedure
1.
Connect an emitter cable (F39-JC
-L, grey, sold separately) to the emitter's connection cable (grey).
2.
Connect a receiver cable (F39-JC
-D, black, sold separately) to the receiver's connection cable
(black).
3.
Connect the 0V line of the power supply directly to the protective earth (PE).
To ensure proper wiring, check that the color of the cable matches the color of the connector's resin cover (emitter: grey,
receiver: black). Failure to do so may result in damage to the F3SJ. Incorrect wiring can be prevented by matching the
colors.
Cable with Connector on One End (F39-JC
A, sold separately)
Internal wiring diagram (F39-JC
A-L, F39-JC
A-D)
Set model name
For emitter
For receiver
L (mm)
F39-JC3A
F39-JC3A-L
Grey cable F39-JC3A-D
Black
cable 3000
F39-JC7A
F39-JC7A-L
F39-JC7A-D
7000
F39-JC10A
F39-JC10A-L
F39-JC10A-D
10000
F39-JC15A
F39-JC15A-L
F39-JC15A-D
15000
F39-JC20A
F39-JC20A-L
F39-JC20A-D
20000
dia.15
39.5
L
8-wire (4-pair) (Cross section of conductor: 0.3mm
2
/insulator diameter: dia. 1.15mm)
(Unit: mm)
M12 Waterproof connector
Insulated vinyl round cable
dia. 6.6, shielded
1
2
3
4
5
6
7
8
+24V DC
0V
+24V DC
0V
Emitter
Receiver
Female
White
Brown
Green
Grey
Pink
Blue
Red
Shield
Shield
Yellow
White
Brown
Green
Grey
Pink
Blue
Red
Yellow
Twisted pair wires are white and red, brown and blue, green and yellow, and grey and pink
Interlock selection input
Test input
Reset input
Auxiliary output 2
External device
monitoring input
Control output 1
Safety output 2
Auxiliary output 1
Communication line (+)
Communication line (-)
Communication line (+)
Communication line (-)
5
8
4
3
2
1
7
6
Connected to connection cable and
Cable with connectors on both ends
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)