What can be done by the setting tool
Setting Example: Configuring a warning zone information for auxiliary output 1
Reverse Output: None
Setting Change
Configure for each CH in case of a series connection.
- If you need output of warning zone’s incidence/interruption status, set output mode of auxiliary output or external
indicator output to warning zone information.
- Auxiliary Output (Non-Safety Output) p.95
- External Indicator Output (Non-Safety Output) p.99
- A warning zone cannot overlap with muting, fixed blanking, nor floating blanking zones.
Warning Zone Label
When a warning zone is configured, you must attach labels that indicate a border between normal
detection zone and warning zone.
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool for F3SJ
Warning Zone
Function
Disable
Disabled/Enabled from upper/
Enabled from lower
3
3
Warning Zone
Setting
0
0 to Number of Beams
3
3
Warning Zone
Detection Zone
Figure 6
Figure 7
Figure 8
Safety output ON
Warning zone output OFF
Safety output ON
Warning zone output ON
Safety output OFF
Warning zone output OFF
F3SJ Unblocked/Blocked
(Warning zone only)
F3SJ Unblocked/Blocked
(Other than warning zone)
Unblocked
Blocked
Auxiliary output 1
(warning zone)
ON
OFF
Unblocked
Blocked
Safety output
ON
OFF
Warning Zone
Detection Zone
Normal beam
Warning beam
DETECTION
ZONE
WARNING
ZONE
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com