81
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Set
ting Adjust
ed
to Appl
ication
What can be done by the setting tool
E
Limitation for Combination with Other Functions
You can use muting, fixed blanking, and floating blanking functions in combination only with the PC
tool for F3SJ. Note that there is a limitation for setting with zones.
The setting console cannot combine these functions.
For details, see Setting Zone Adjacent Conditions p.92 .
Setting Zone Adjacent Conditions p.92
Muting Function
Overview
Configures muting function.
The muting function disables safety functions of the device. You must ensure safety using other
measures during this function is enabled.
Install muting sensors so that they can distinguish between a person and an object that is being
allowed to pass through the detection zone.
All muting lamps (external indicators) that indicate state of muting function must be installed where
workers can see them from all the operating positions.
Muting related time must be properly configured for its application by a sufficiently trained and qualified
person, and the person must have responsibility for settings, especially when setting the muting time
limit to infinite.
Use independent 2 input devices for muting input.
You must install F3SJ, muting sensor, and physical barrier, and configure time settings for muting so
that an operator should not enter hazardous zone.
Example
•Only workpieces should pass through a conveyor entry
•Muting function should work for only a specified zone
•Other muting mode should be configured than standard muting which is not suitable for your
application
Functional Description
• Muting Function
• Operation Mode
PC tool for F3SJ allows selection of 3 operation modes for muting function:
1. Standard Muting Mode
2. Exit Only Muting Mode
3. Position Detection Muting Mode
• Muting Zone Setting
Setting tool provides designation of beams for muting. (All beams are specified for factory shipment)
You can specify a beam by teaching, with which the sensor learns muting beams as those interrupted,
or manually.