64
Ch
apt
e
r
3
F3SJ
St
at
us
When
Set
ting
T
ool Is
Conne
ct
ed
F3SJ-A
User’s Manual
What can be done by the setting tool
Internal Indicator While Writing/Monitoring with the Setting
Tool
When using the setting tool to write settings to the F3SJ or while monitoring the incident light level
indicator, the [BLANKING (TEST)] indicator and an indicator on receiver's power connector side (see
below) blink.
When accessing at the administrator level, the indication lamps blink twice per second, and when
accessing at user level, they blink once per second.
For details about administrator level and user level, see p.65
While writing/monitoring with setting tool (Safety output is OFF)
Emitter
Receiver
Administrator level: Blinks twice
User level: Blinks once
OFF
PO WER
INTLK
EDM
B LA N KIN G
(TEST)
O N
O FF
EMITTER
RECEIVER