System Configuration and Functions
Wiring Diagrams
Wiring When Using Muting and External Device Monitoring Function
S1
: External test switch (connect to 0V if a switch is not required)
S2
: Lockout reset switch (connect to 24V if a switch is not required)
A1
: Contact by muting sensor A1
B1
: Contact by muting sensor B1
K1,K2 : Relay or other device that controls hazardous parts of the machine
M1
: Muting lamp
Muting input 1 (White)
Muting input 2 (Red)
K3
:
Load or PLC, etc. (for monitoring)
*1 Use a switch for small loads (input specifications: 24V, 1.8mA)
*2 Can work as an interlock reset switch when interlock function is used. (Configuration by the setting tool is required)
*3 F3SJ operates even when K3 is not connected.
*4 Connect a muting lamp to either of external indicator output or auxiliary output 1 of an emitter or a receiver.
To connect a muting lamp to the auxiliary output 1, setting must be changed by the setting tool.
M1 *4
K1
K2
S1
*1 *1 * 2
S2
A1
B1
* 3
* 4
K1
K2
K3
+24V DC
0V
Emitter
Receiver
(Grey) Communication line (+)
(Pink) Communication line (-)
0V(Blue)
0V(Blue)
Power
supply
Shield
Shield
T
est input(Green)
Reset input(Y
ellow)
24V(Brown)
24V(Brown)
External device
monitoring input (Red)
Auxiliary output 1(Y
ellow)
Safety output 1(Green)
Safety output 2(White)
*4
5
5
*
*
5
*
Two-wire type sensor cannot be used.