59
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Us
ing the
Se
tt
in
g Tool
What can be done by the setting tool
E
List of Functions that Can Be Changed by the Setting Tool
3
: Available
–: Unavailable
*1 New functions added for Version 2. They can be enabled by the setting tool and their settings can
be read by the tool.
*2 Available without using the setting tool. Finer functional setting can be done by the setting tool. For
these functions, see Chapter 2.
Function/Monitor Item
Setting Console
PC Tool for F3SJ
F39-MC21
F39-GWUM
Setting Adjusted to Application
Fixed Blanking Function
*1
3
3
Floating Blanking Function
*1
3
3
Warning Zone Function
*1
3
3
Muting Function
(For muting system)
*2
3
3
Override Function
(For muting system)
*2
3
3
Indicator/Input & Output Setting
Auxiliary Output
*2
3
3
Designated Beam Output Function
*1
–
3
External Indicator Output
*2
3
3
Interlock Function
*2
3
3
External Device Monitoring Function
*2
3
3
Operating Range Change
Operating Range Change Function
*1
3
3
Operation Monitoring
Incident Light Level Display
*1
3
3
Disturbance Light Level Display
*1
3
3
Status Information Display
*1
–
3
Maintenance Information
Error History
*1
3
3
Power-on Time
*1
3
3
Load Switching Frequency
*1
3
3
Setting Recovery
Setting Recovery Function
*1
3
3
Other
Safety Distance Calculation Function
*1
–
3
Connection Cable Length Calculation
Function
*1
–
3
Rated Response Time Check
*1
3
3