8 Using Expansion Units and Expansion I/O Units
8-80
CP1E CPU Unit Hardware User’s Manual(W479)
W10.00
2
D0
MOV(021)
#7FFF
2
=(300)
#7FFE
2
<>(305)
W10.01
3
D1
MOV(021)
#7FFF
3
=(300)
#7FFE
3
<>(305)
W10.02
4
D2
MOV(021)
#7FFF
4
=(300)
#7FFE
4
<>(305)
W10.03
5
D3
MOV(021)
#8000
5
=(300)
#7FFE
5
<>(305)
Detects initialization complete
Stores input 0’s data in D0.
Stores input 1’s data in D1.
Stores input 2’s data in D2.
Stores input 3’s data in D3.
ON when an open-circuit alarm has been
detected for thermocouples input 2.
ON when an open-circuit alarm has been
detected for thermocouples input 2.
ON when an open-circuit alarm has been
detected for thermocouples input 2.
ON when an open-circuit alarm has been
detected for analog input 3.