![background image](http://html.mh-extra.com/html/omron/cp1e-e-d-series/cp1e-e-d-series_user-manual_742511131.webp)
5-13
5 Installation and Wiring
CP1E CPU Unit Hardware User’s Manual(W479)
5-2 In
stallat
ion
5
5-
2-4 C
onnecting Expansio
n I/O U
nits and Expansio
n Units
The following restrictions apply to the CP-series Expansion Units and Expansion I/O Units that can be
connected to CP1E CPU Units.
Maximum Number of Connectable Units
With an E30/40/60(S), N30/40/60(S
) or NA20 CPU Unit, a total of up to three Expansion I/O Units
and Expansion Units can be connected to one CPU Unit. It is not possible to connect Expansion I/O
Units and Expansion Units to E10/14/20(S) or N14/20 CPU Units.
Precautions on Connecting Units