background image

o 400

USER GUIDE

For Service Call Scorpion Group - 01452 525397

THANK YOU FOR VOTING TEXECOM

Summary of Contents for Veritas R8 Plus

Page 1: ...o 400 USER GUIDE For Service Call Scorpion Group 01452 525397 THANK YOU FOR VOTING TEXECOM ...

Page 2: ...ss Zone Number s Press Prog or Reset Enter Your Code Press Reset Chime Zones Enter Your Code Press Chime Press Zone Number s Press Prog Chime On Off Press Chime Test Sounders Strobe Enter Your Code Press Prog Enter 05 Press 3 Internal Sounder Press 2 Strobe Press 1 Bell Press Reset Press Reset Walk Test Enter Your Code Press Prog Enter 06 Conduct Walk Test Press Reset Press Reset Conduct Walk Test...

Page 3: ...ult cannot be corrected contact your alarm company Your Installer can program the system so that it can be set using the or keys without the need to first enter a User code To FULL Set the System Ensure all zones are closed e g windows and doors Enter your 4 digit code The Unset light will flash Press The exit tone will sound Leave the premises When the system has set the exit tone will stop To PA...

Page 4: ...o complete the omitting procedure The system will revert to exit mode The exit tone and exit timer will restart 1 The system may be programmed so that some zones cannot be omitted 2 The system will automatically revert to exit mode 16 seconds after the last key is pressed 3 Whilst omitting included zones that are in fault are indicated by flashing 4 Omitted zones that are not in fault flash during...

Page 5: ... opened zones if any To cancel the display and stop the external strobe press The system will chime and return to unset If the System Requires an Anti Code After an Alarm Activation The system may be programmed to require an Anti Code after an alarm activation You will still be able to silence the alarm by entering your code as normal However you will not be able to reset the system without first ...

Page 6: ...obe The control panel has a test facility to check the operation of the internal sounder the external sounder and strobe Enter your 4 digit code The Unset light will flash Press All the zone lights will illuminate Enter All the zone lights will turn off The system outputs may be tested as follows Key System Output Internal sounder at high level alarm level Internal sounder at low level entry exit ...

Page 7: ...st by triggering each of the system s detection devices in turn and check that the control panel registers the corresponding zone as open To terminate Walk Test press All the zone lights will illuminate Press again The system will return to unset and all the zone lights will turn off To Change Your Code Before changing your code it is vital that you memorise or write down the new code you are abou...

Page 8: ...s Telephone Installation Date Zone Allocation Zone Full Set Part Set 1 Part Set 2 Part Set 3 Part Set 4 Area Protected 1 2 3 4 5 6 7 8 Tick Zones Included in Full Part Sets Service Record For Service Call Scorpion Group Security 01452 525397 System Due for Maintenance System Serviced Servicing Engineer Anti Code Phone Number If Required ...

Reviews: