![background image](http://html1.mh-extra.com/html/omron/c200h-asc11/c200h-asc11_manual_742476068.webp)
58
Closing a Communications Port
Section 4-5
Port #2: KYBD
Device Symbol: SCRN or LPRT
Port #1: SCRN or LPRT
CTS
CTS_ON
No check
No check
No check
No check
No check
CTS_OFF
No check
No check
No check
No check
No check
DSR
DSR_ON
No check
No check
No check
No check
No check
DSR_OFF
No check
No check
No check
No check
No check
Command
Mode
Open
Receive data
Send data
Close
OFF
RTS_OFF
ON
RTS
RTS_ON
ON
RUN
Command
Mode
OFF
DTR
ON
OFF
None
None
Status depends on DTR command
CTS
CTS_ON
No check
No check
Check
No check
No check
(during send)
CTS_OFF
No check
No check
No check
No check
No check
DSR
DSR_ON
No check
No check
Check
No check
No check
DSR_OFF
No check
No check
No check
No check
No check
Command
Mode
Open
Receive data
Send data
Close
OFF
RTS_OFF
ON
RTS
RTS_ON
ON
RUN
Command
Mode
OFF
OFF
None
None
None
DTR
ON