GETTING STARTED GUIDE

NI 9205

16 AI Differential/32 AI Single-Ended, ±200 mV
to ±10 V, 16 Bit, 250 kS/s Aggregate

Summary of Contents for NI 9205

Page 1: ...GETTING STARTED GUIDE NI 9205 16 AI Differential 32 AI Single Ended 200 mV to 10 V 16 Bit 250 kS s Aggregate...

Page 2: ...Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9205 only as described in this document Cauti...

Page 3: ...Channel to COM 30 VDC NI 9205 with Spring Terminal Isolation Voltages Channel to channel None Channel to earth ground2 Continuous 250 Vrms Measurement Category II Withstand 2 300 Vrms verified by a 5...

Page 4: ...for U S or 230 V for Europe Caution Do not connect the NI 9205 to signals or use for measurements within Measurement Categories III or IV NI 9205 with DSUB Isolation Voltages Channel to channel None C...

Page 5: ...parts of equipment circuits powered by regulated low voltage sources and electronics Caution Do not connect the NI 9205 to signals or use for measurements within Measurement Categories II III or IV S...

Page 6: ...dous voltage LIVE 42 4 Vpk 60 VDC you must ensure that devices and circuits connected to the module are properly insulated from human contact You must use the NI 9940 connector backshell kit to ensure...

Page 7: ...dous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution F...

Page 8: ...Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution You must make sure that tra...

Page 9: ...duct is operated in the intended operational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the...

Page 10: ...s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements...

Page 11: ...60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude NI 9205 with spring terminal 2 000 m NI 9205 with DSUB 5 000 m I...

Page 12: ...Connecting the NI 9205 The NI 9205 provides connections for 32 single ended channels or 16 differential channels 12 ni com NI 9205 Getting Started Guide...

Page 13: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 AI0 AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI16 AI17 AI18 AI19 AI20 AI21 AI22 AI23 COM DO0 AI8 AI9 AI10 AI11 AI12 AI13 AI1...

Page 14: ...d reference DO Digital output channel3 PFI Programmable function interface signal that functions as a digital input Signals You can connect single ended or differential signals to the NI 9205 Use a di...

Page 15: ...al connection configurations with the NI 9205 Table 2 Differential Pairs Channel AI AI 0 AI0 AI8 1 AI1 AI9 2 AI2 AI10 3 AI3 AI11 4 AI4 AI12 5 AI5 AI13 6 AI6 AI14 7 AI7 AI15 16 AI16 AI24 17 AI17 AI25 N...

Page 16: ...Table 2 Differential Pairs Continued Channel AI AI 18 AI18 AI26 19 AI19 AI27 20 AI20 AI28 21 AI21 AI29 22 AI22 AI30 23 AI23 AI31 16 ni com NI 9205 Getting Started Guide...

Page 17: ...the NI 9205 NI 9205 MUX ADC PGIA Vcm AI0 CH0 AI8 CH0 AI1 CH1 AI9 CH1 COM V1 V2 In a differential configuration the NI 9205 rejects the common mode noise voltage Vcm during the measurement of V1 To co...

Page 18: ...X ADC PGIA Vcm AI0 CH0 AI8 CH0 AI1 CH1 AI9 CH1 COM V1 V2 To connect floating differential signals to the NI 9205 you must connect the negative signal to COM through a 1 M resistor to keep the voltage...

Page 19: ...an RSE configuration the NI 9205 measures each channel with respect to COM To connect RSE signals to the NI 9205 you must connect the voltage ground signal to COM to keep the maximum working voltage i...

Page 20: ...renced single ended NRSE signals to the NI 9205 Figure 5 Connecting an RSE Voltage Signal to the NI 9205 NI 9205 MUX PGIA ADC V1 V2 COM AI1 AISENSE AI0 In an NRSE configuration the NI 9205 measures ea...

Page 21: ...g Terminal Connector Complete the following steps to connect wires to the spring terminal connector using the flathead screwdriver that is included with your C Series module or a flathead screwdriver...

Page 22: ...ert the screwdriver into a spring clamp activation slot to open the corresponding connector terminal 2 Press a wire into the open connector terminal 3 Remove the screwdriver from the activation slot t...

Page 23: ...Connections If your application is subject to high vibration NI recommends that you use the NI 9940 backshell kit to protect connections to the NI 9205 with spring terminal NI 9205 Getting Started Gui...

Page 24: ...CompactRIO NI CompactDAQ RELATED INFORMATION Software Support Related Documentation ni com info softwareversion Services ni com services NI 9205 Datasheet NI RIO Help LabVIEW FPGA Help NI 9205 Datashe...

Page 25: ...duct Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council o...

Page 26: ...cts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information a...