Initial Drive configuration
To be able to connect the Servo Drive through CN3 to the TJ2-KS02, this
interface has to be enabled. To do so, parameters Pn628 and Pn629 need to
be changed.
Sequence I/O Signal
Input Signals
When the option unit interface is enabled, the following additional functions
can be allocated to the multi-function inputs (SI1 to SI10):
Pn
number
Parameter
name
Description
Default
setting
Unit
Setting
range
Power
supply
OFF
to ON
628
Special
function
selection
Set to 1 to enable the
option unit interface
0
-
0 or 1
Yes
629
Option unit
timeout
Time to wait for response
from the option unit.
100
ms
100 –
10000
Yes
Signal name
Symbol
Set value
Input terminal
that can be allocated
NO
NC
Latch input 1
EXT1
20h
Alarm 33
SI4 only
Latch input 2
EXT2
21h
Alarm 33
SI5 only
Homing input
HOME
22h
A2h
SI1-SI10