User’s Guide Océ CS9060 printer
Chapter 3 : Installing the Unit
37
AP-75770 – Rev 1.1 -19/11/2007,
3.6 DISPOSAL OF WASTE FLUIDS.
(1) Disposal period.
Dispose the waste fluids in the following cases.
¾
When the waste fluid tank is more than half full.
¾
When “Waste Ink Tank Full” is displayed on the operation panel.
(2) Disposal method.
Important
•
The waste fluid from the printer is industrial waste. Proper waste fluid disposal according to
industrial waste disposal laws and ordinances of your local government is required. Consign
disposal of waste fluids to a specialized processor.
Step 1 :
Prepare an empty container such as a supply waste fluid bottle, to contain the waste fluid.
Step 2 :
Lay a protective material on the floor under the waste fluid tank.
Step 3 :
Open the waste fluid valve, and transfer the waste fluid to the container.
Notes
•
When transferring the waste fluid to the empty container, put the container close to the waste fluid
valve, so it could not splash.
1
2
No. Name
1
Waste fluid valve
2 Empty
container
Step 4 :
After transferring the waste fluid to the empty container, close the waste fluid valve securely.
1
2
Step 5 :
Wipe the opening of the waste fluid valve with a cloth, etc.
•