Service Calibrations
4-27
The control panel asks whether to accept the current head
heights.
12.
Press
to save the calibration.
The control panel prompts you to remove the head height
gauge and ensure that the platen is clear of all obstructions.
13.
Press
(Proceed) to return the carriage to its home
position.
14.
The control panel prompts you to press
(Proceed) to
complete the calibration.
15.
Press
(Proceed).
The control panel asks whether you want to perform a media
thickness calibration next (required).
•
To perform a media thickness sensor calibration, press
. Then go to the next section, “Calibrating the Media
Thickness Sensor” on page 4-28.