Manual Calibrations
4-23
•
Press
(Proceed). The control panel displays this
message:
Do you want to clear the hard bad jets?
•
Press
No
to clear the soft bad jets only.
•
Press
Yes
to clear both the hard and soft jets.
The control panel displays this message:
All reported bad jets have been cleared.
25.
Press
(Proceed).
When you have finished mapping jets, the following sum-
mary appears on the control panel:
x soft jets currently reported bad.
x hard jets currently reported bad.
x new soft bad jets reported.
x new hard bad jets reported.
x previous soft bad jets cleared.
x previous hard bad jets cleared.
where x is the number of jets.
Print Jet-Out Lines
This option prints a version of the Prime Bars in which missing
jets that are replaced are marked with a black square.
Default Registration Data
This option resets all registration data. Since there is no registra-
tion data after running this option, all calibration values must be
reestablished by running the calibrations.