A-4
Specifications
•
220 VAC, 16 Amps, single phase, with IEC 60309 wall
receptacle (Europe)
North America: If your building receives power from a standard
three-phase supply, note that the printer will use only two of the
three phases. This means that your building’s three-phase
power transformer may have an unbalanced load. Check with
your electrician to verify that your building has sufficient capacity
for this unbalanced load.
Optional Auxiliary Power for Vacuum/Pressure System:
A 24 volt DC power supply with universal adapters is included
with the printer. It can be connected from the 24 VDC jack on the
rear of the printer to either of two options:
•
UPS — customer-supplied uninterruptible power supply, out-
put 100-240 VAC, 50/60 Hz, minimum of 15 watts of power,
provides battery backup to the vacuum system in the event
of a power failure.
•
Wall outlet — 100-240 VAC, 50/60 Hz, provides temporary
power to the vacuum system when it is necessary to power
down the printer for service.
Use of the auxiliary power supply is optional, but if power is
unexpectedly removed from the printer, printhead vacuum will
be lost and ink will leak from the printheads. The amount of ink
lost will be limited to the ink currently in the printheads, not the
ink in the ink supply boxes which as not yet been pumped to the
printheads.
NEMA L6-20R
locking wall receptacle
(North America/Japan)
IEC 60309
wall receptacle
(Europe)
Summary of Contents for CS7400 Series
Page 1: ...Oc CS7400 Series User Manual 0706443 Rev B intro fm Page i Wednesday October 31 2007 9 06 AM...
Page 8: ...viii Table of Contents...
Page 58: ...2 28 UV Lamp Operation and Maintenance...
Page 72: ...3 14 Menus...
Page 79: ...Auto Calibrations 4 7 Fig 4 1 Auto calibration patterns and reports...
Page 105: ...Technical Specifications A 1 Appendix A Technical Specifications...
Page 119: ...Index 1 Index...
Page 122: ...Index 4...