56
DL-V3 Firmware Reference Manual Rev 2
Chapter 2
DL-V3 Commands
2.28 METHUMID
Specify Air Humidity
The
methumid
command allows you to specify air humidity. Humidity specified with the
methumid
command does not affect receiver operation. Rather, it allows you to create a record of atmospheric
conditions for post-processing purposes.
The
methumid
set
command specifies air humidity at
humid
. This command only stores the humidity
value in volatile memory, and does not automatically generate a record. The humidity value can then
be displayed/recorded by requesting the
met
log.
The
methumid
clear
and the
methumid
default
commands clear the humidity setting
.
Syntax
methumid
set [
humid
]
methumid
default|clear
Message ID = 163
Table 37: METHUMID Default Configuration
Field
Data
Value Used if
Not Specified
Bytes
Format
Units
Offset
1
Header
-
-
-
0
2
Parameter Update, see
-
4
Enum
none
H
3
Humidity
0
4
Float
percent
H+4
Parameter
Power-On
Freset
Stored in NVM
methumid
clear
clear
NO