DL-V3 Commands
Chapter 2
DL-V3 Firmware Reference Manual Rev 2
29
2.9
FRESET
Clear Selected Data from NVM and Reset
The OEMV
freset
command is extended to include DL-V3 features. An additional target field,
userdata
(value = 10), resets only the DL-V3 user data NVM, thereby resetting all parameters
indicated in this document as “Stored in NVM” to factory defaults. Issuing the
freset
command with
the “target” field set to
standard
, resets the userdata NVM as well as OEMV parameters as indicated
in the
OEMV Family Firmware Reference Manual
.
The DL-V3 factory default command list is on
.
If you issue the FRESET command without any parameters, it is the same as issuing a FRESET
STANDARD command.
Table 13: FRESET Target
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1
FRESET
header
-
-
This field contains the command
name or the message header
depending on whether the
command is abbreviated ASCII,
ASCII or binary, respectively.
-
H
0
2
target
Data to be reset by the receiver
Enum
4
H
Binary
ASCII
Description
0
STANDARD
Resets commands, ephemeris, and almanac
(default). Also resets all L-Band related data except
for subscription information.
1
COMMAND
Resets the stored commands (saved configuration)
2
GPSALMANAC
Resets the stored GPS almanac
3
GPSEPHEM
Resets the stored GPS ephemeris
4
GLOEPHEM
Resets the stored GLONASS ephemeris
5
MODEL
Resets the currently selected model
10
USERDATA
Reset DL-V3-only commands
11
CLKCALIBRATION
Resets the parameters entered using the
CLOCKCALIBRATE command
20
SBASALMANAC
Resets the stored SBAS almanac
21
LAST_POSITION
Resets the position using the last stored position
31
GLOALMANAC
Resets the stored GLONASS almanac