• FILE
Save this log to the receiver’s CF card
• NO_PORTS
No port specified
• THISPORT
Current COM port
If the group is intended for use in a stand-alone mode of operation, choose FILE to save the logs to the
DL-V3’s internal CF card. You can save ASCII or binary format logs to the FILE destination.
Choose a log output format from the
Format
list, ASCII or binary.
The trigger and period settings can be edited by using the fields in the
Trigger
and
Period
sections of
the
Logs
tab
.
A log’s trigger and period information is what determines when and how often the DL-V3 receiver
collects that log’s information. For example, if the trigger and period for the compressed range
measurements log (RANGECMP) is set to OnTime 2, the receiver logs compressed range
measurements every two seconds. For 2 Hz (twice per second), use an OnTime 0.5
trigger.
To edit trigger information for a particular log, first select a trigger from the
Trigger
drop down box.
The
Period
drop down box appears dim unless
OnTime
is selected as the trigger. In this case, you can
edit the number of seconds directly or choose a time period from the
Period
drop down box.
explains your choices.
Table 71: Log Triggers
Click on the Add button to add the log details to the group. Continue to add logs until your group
contains the logs you want. To remove a log from the group, select the log in the
Logs
table, and click
on the
Remove
button.
To edit a log in a receiver group, select it, change the settings and click on the
Add
button again. The
log appears twice in the table. Select the log with the old settings and click on the
Remove
button.
Click the
OK
button to save your changes or the
Cancel
button to discard your changes. The logs you
have selected are displayed along with their descriptions, default destination and interval settings.
4.2.1.2
Preset POWERUP Group
Your
DL Explorer
software is set up with a preset receiver group. Below is an outline of the
Trigger
Description
ontime
You specify when the receiver should collect the information. For example, if you
specify On Time 5, the information is collected every 5 seconds.
onchanged
Output only if the message changes. For example, if you select the almanac log
(RAWALMB), you can choose the On Changed option so when a log group is run,
the receiver collects almanac information once and not again unless the almanac
information changes.
once
Output only the current message.
onnew
Output when the message is updated (not necessarily changed).
onnext
Output only the next message.