Troubleshooting
6-4
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Too Little Material
Problem
Possible Cause
Corrective Action
Material supply hole to
pump or pump suction hole
partially clogged
−
Detach pump and clean supply
hole or suction hole
Tank isolation valve not
completely open
−
Open
Filter cartridge partly
clogged
−
Clean or replace filter screen
Pressure control valve
defective
−
Clean or replace
Processing temperature set
too low
−
Correct temperature setting
Pump block of the gear
pump worn
−
Replace pump
Material Pressure too High
Problem
Possible Cause
Corrective Action
Safety valve or pressure
control valve dirty and thus
blocked
−
Disassemble and clean or replace
Safety valve or pressure
control valve defective
−
Replace
Pressure control valve set
incorrectly
−
Set to default
Pneumatic safety valve
(option) pressurized with
too high pressure
−
Reduce pressure