Technical Data
9-3
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Electrical Data
WARNING:
The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Type designation
VBN 50
VBN 100
VBN 200
VBN 50/50 VBN 50/100
VBN 100/100
Available operating voltages
200
−
240 V
AC
3-phase without neutral (
Delta
)
380
−
415 V
AC
3-phase with neutral (star
−
WYE
)
Permissible voltage
deviations
Power supply:
"
10%
I/O:
"
10%
Operating voltage
frequency
50/60 Hz
Melter fuse protection
Refer to ID plate
Key-to-line
Max. input
0 to 10 V
DC
Max. no. of gun/hose
connections
18
18
26
26
26
26
Max. load, gun/hose
connections
Per gun or hose [W]
2000
2000
2000
2000
2000
2000
Per gun/hose pair [W]
4000
4000
4000
4000
4000
4000
Total [W]
46000
46000
46000
46000
46000
46000
Max. melter load [W]
58100
68700
82900
72800
81350
89900
Max. no. of ext. motor
controllers
6
6
6
6
6
6
Max. no. of ext. analog
pressure inputs
8
8
16
16
16
16
Max. no. of ext. digital
pressure inputs
12
12
12
12
12
12
Max. no. of channels for
Air Run-up
16
16
16
16
16
16
Summary of Contents for VersaBlue 100H/100H
Page 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...