Maintenance
5-7
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Tank
Draining Material
1. Place a container under the drain valve and open the ball valve.
2. Feed the material out of the drain valve and collect it.
3. Close the ball valve and dispose of the material properly according to
local regulations.
4. OR: Allow the melter pump(s) to run until the material has drained from
the melter.
CAUTION:
Do not feed charred material through the gun. Particles can
block the gun. Instead unscrew the hose and feed the material out through
the hose connection (Refer to section
Installation
).
Cleaning Tank by Hand
Cold material can usually be peeled off of the sides of the tank
(Refer to Fig. 5-4). If necessary, first heat tank to material softening
temperature, usually approx. 70
°
C / 158
°
F.
NOTE:
The inside of the tank is release coated. Do not use metallic tools to
clean. Do not use wire brushes! This could damage the release coating.
Fig. 5-4
Retightening Fixing Screws
Heating and cooling that occurs during daily operation can cause the fixing
screws to loosen. Retighten screws as indicated in the table.
NOTE:
Retighten fixing screws only using a torque wrench and when the
melter is cold.
Fig. 5-5
Connection
Thread
Torque
Tank / melter chassis
M 8
25 Nm / 220 lbin
Grid (low melt) / reservoir (high melt)
M 8
20 Nm / 177 lbin
Summary of Contents for VersaBlue 100H/100H
Page 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...