Repair
7-3
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Attaching Gear Pump
NOTE:
The gear pump may only be screwed on when the melter is cold.
NOTE:
The sealing surfaces on the plate and the pump must be clean.
Always replace any O-rings.
Required tool: Torque wrench
1. Apply high temperature grease (Refer to section
Maintenance,
Processing Materials
) to the new pump.
CAUTION:
Pump types SF and DF seal metallically. Do not apply
high-temperature grease.
2. Apply high temperature grease (Refer to section
Maintenance,
Processing Materials
) to the pump fixing screws and attach only when
the tank is cold. Tighten screws crosswise using a torque wrench.
Torque: 25 Nm / 220 lbin for pump types
SN
and
DN
.
Torque: 50 Nm / 440 lbin for pump types
SF
and
DF
.
3. Refer to
Important Regarding Coupling
The axial offset, meaning the sum of the four gaps (4, Fig. 7-3), must
result in at least 2 mm (0.08 in) of air to accommodate the heat
expansion during operation.
Permitted radial offset: 1 mm (0.04 in)
Permitted angular offset: 1
°
4. Slide coupling half onto the shaft of the new pump.
5. Center the coupling disks (1) to one another and allow the coupling links
(2) to hang vertically (Refer to Fig. 7-3). Turn the coupling half on the
motor shaft to its position by hand.
6. Tighten coupling screws (3).
7. Heat melter to operating temperature and open tank isolation valve
again.
Fig. 7-3
Summary of Contents for VersaBlue 100H/100H
Page 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...