Maintenance
5-2
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Processing Materials
Designation
Order number
Use
High temperature grease
To be applied to O-rings and
threads
NOTE:
The grease may not be
mixed with other lubricants.
Oily/greasy parts must be cleaned
before application.
S
Can
10 g
P/N 394769
S
Tube
250 g P/N 783959
S
Cartridge
400 g P/N 402238
Temperature-resistant
adhesive
Loctite 640
Secures screw connections
S
50 ml
P/N 290359
Heat transfer compound
NTE303
To improve heat conducting of
temperature sensors
S
1 g
P/N 1023441
Preventive Maintenance
The maintenance intervals are general guidelines based on experience.
Depending on the operating environment, production conditions and melter
hours of operation, other scheduled maintenance tasks may prove
necessary.
NOTE:
Coupling and motor controller are maintenance-free.
Melter part
Activity
Interval
Refer to
Complete melter
External cleaning
Daily
5-4
Inspect for external
damage
Daily
5-5
Purge melter with
cleaning agent
When material is changed
5-6
Displays and lamps
Safety and function tests Daily
5-5
Safety valve
Activate piston
Monthly
5-6
Tank
Clean tank by hand
When there is material residue in
tank
5-7
Retighten fixing screws
Every 500 hours of operation
5-7
Power cable
Inspect for damage
Every time the melter is serviced
−
Air hoses
Inspect for damage
Every time the melter is serviced
−
Summary of Contents for VersaBlue 100H/100H
Page 46: ...Installation 3 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 74: ...Maintenance 5 24 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 94: ...Repair 7 14 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...
Page 96: ...Parts 8 2 P N 7146386A E 2008 Nordson Corporation VBN w o Control System...