If a DC voltage reads 4.5 to 5V, the SSR is receiving
a signal to turn on the zone. If no voltage is present,
verify the continuity of the wiring between the HC1-X
or HC2 controller remote terminal and SSR board #
681686-1. If all the wiring checks out, the controller
itself may be faulty and should be replaced.
c. The next step is to check SSR output. Using a
voltmeter set to AC voltage scale greater than or
equal to voltage input of the machine, probe terminals
1 and 2. If voltage reading is equal to machine input
voltage, the SSR is not conducting and should be
replaced (
See
Maintenance Procedures
). If no
voltage is read on the meter, the SSR is functioning
properly.
2. Verify that the blower motor for the suspect zone is functioning. If
it is not, see
Troubleshooting Guide, section X
.
See also Troubleshooting Guide, section VI.
IV. Computer reports
a high deviation of a
heat zone or a zone
overheating.
Check For:
A. Software
5. Choose
Channel setup from the Window menu. Select the
Heat zone channel in question using arrow key. (A typical
alarm screen for a heat zone is shown in
figure 8
).
Summary of Contents for TCM-2200
Page 5: ...1 Introduction ...
Page 6: ...2 ...
Page 18: ...14 ...
Page 19: ...15 Facility Installation ...
Page 20: ...16 ...
Page 26: ...22 ...
Page 27: ...23 Operating System Software Guide ...
Page 28: ...24 ...
Page 55: ...51 ...
Page 56: ...52 ...
Page 57: ...53 ...
Page 58: ...54 ...
Page 64: ...60 ...
Page 65: ...61 Standard and Optional Equipment Operating Guide ...
Page 66: ...62 ...
Page 71: ...67 Troubleshooting Guide HC1 X or HC2 controller ...
Page 72: ...68 ...
Page 74: ...70 ...
Page 95: ...91 Figure 12 ...
Page 107: ...103 Maintenance Procedure ...
Page 108: ...104 ...
Page 110: ...106 ...