18
II. General Operating Conditions
Ambient Operating Temperature - The equipment should be operated in an ambient temperature
range of 5 to 32
o
C (41 to 89.6
o
F) under no load to full load conditions.
Relative Humidity - The equipment should operate within a relative humidity range of 20% - 95%
(non-condensing).
Altitude - The equipment should be limited to be used at altitudes up to 1500 m above mean sea
level.
Transportation and Storage - The equipment is designed to withstand storage and transportation
temperatures within the range of -25°C to 55
o
C (-13°F to +131
o
F). Suitable means are provided to
prevent damage from excessive moisture, vibration, stress and mechanical shock during shipment.
Specification Compliance
Limits/Immunity
Level
Radiated Emission
EN 55011
Meets Group Class A Limits
Radiated RF Immunity
EN 61000-4-2
80 -1000 MHz & 900+5 MHz @ 10V/m
Sound/Noise Level
SEMI S2.27.1
Maximum - 67db
Vibration
MIL-STD-45662A
Maximum - 0.07G
III. Power Requirements
Table 1
shows the service conductor current capacity required for all Asymtek oven models. Use
branch over-current device rated at amperes described in tables below. Please refer to the serial tag
on the machine and/or warning labels near the main terminals for the correct machine voltage and
current. Caution: Use a voltmeter to verify the proper voltage before connecting the machine.
Table
1A
shows standard oven required current capacity.
Model Voltage
⇒
⇓
208, 240 Volts
3 phase (50/60 Hz)
380, 400, 415 or 480 Volts
3 phase (50/60 Hz)
TCM-2200
100 Amps / phase
100 Amps / phase
TCM-3300
100 Amps / phase
100 Amps / phase
TCM-4600
130 Amps / phase
100 Amps / phase
Table 1A
CE Models are wired for either 63 Amps or 100Amps as a maximum current draw for high and low
voltages. Please refer to the serial tag for correct voltage and current.
Table 1B
shows CE oven
required current capacity. For other currents or voltages, please consult the factory.
Model Voltage
⇒
⇓
208, 240 Volts
3 phase (50/60 Hz)
380, 400, 415 or 480 Volts
3 phase (50/60 Hz)
TCM-2200
63 or 100 Amps / phase
63 or 100 Amps / phase
TCM-3300
63 or 100 Amps / phase
63 or 100 Amps / phase
TCM-4600
100 Amps/phase
63 or 100 Amps / phase
Table 1B
Summary of Contents for TCM-2200
Page 5: ...1 Introduction ...
Page 6: ...2 ...
Page 18: ...14 ...
Page 19: ...15 Facility Installation ...
Page 20: ...16 ...
Page 26: ...22 ...
Page 27: ...23 Operating System Software Guide ...
Page 28: ...24 ...
Page 55: ...51 ...
Page 56: ...52 ...
Page 57: ...53 ...
Page 58: ...54 ...
Page 64: ...60 ...
Page 65: ...61 Standard and Optional Equipment Operating Guide ...
Page 66: ...62 ...
Page 71: ...67 Troubleshooting Guide HC1 X or HC2 controller ...
Page 72: ...68 ...
Page 74: ...70 ...
Page 95: ...91 Figure 12 ...
Page 107: ...103 Maintenance Procedure ...
Page 108: ...104 ...
Page 110: ...106 ...