101
XII. The machine is
always in a warning
condition.
Check For:
Choose Channel Setup from the Window menu and verify that the
warning deviation is set greater than the dead band. The dead-band is
factory set to 2. Verify these settings for any channel displaying a
warning.
XIII. The machine trips
breakers.
Check For:
A. Heater breakers
Heater or wiring may have shorted to ground.
See
Troubleshooting
Guide,
sections III and IV
.
B. Q26
C. Q27
D. Q28
E. Q29
F. Q30
For High Voltage Ovens only, Check oven transformer T1.
Check all blower motors and muffin fans for operation one by one.
Check hood lift circuit and Battery Backup (if installed) input.
The 24 VDC power supply may be faulty and should be replaced.
The conveyor drive motor may be faulty or overloaded.
See
Troubleshooting Guide,
section XIV
.