74
D. Computer
1. Verify that the computer and monitor are plugged in and turned
on.
2. Check for voltage on the computer outlet. Voltage should be 240
VAC. (For low voltage machines, voltage should be 208-240V.)
3. Check for tripped breaker Q31 located at left end of electrical
panel.
4. Check the computer itself by plugging it into another outlet.
(Computer will work on 120V or 240V)
Note: Set the power selector switch (located on backside of the
computer) for the applicable voltage.