+
+
+
+
+
Black
Red
remove the
insulation devices
for 3x7Ah
Red
Black
Figure 4.1:
Wiring Diagram of a 12V External Battery Rack Unit (2 or 3x7Ah in parallel)
+
+
+
+
+
+
+
+
+
Black
Red
remove the
insulation devices
for 3x7Ah
Red
Black
Black
Red
Figure 4.2:
Wiring Diagram of a 36V External Battery Rack Unit (1 or 2x7Ah in parallel)
This type of unit is only used for an OXO Connect L platform.
Procedure
Position the 12V - 7Ah external batteries in the battery rack unit (maximum 3 batteries for an OXO
Connect M platform and 6 batteries for an OXO Connect L platform).
1.
Open the external battery unit and position the batteries vertically in the unit.
2.
Make all the connections after having removed, if necessary, the insulation devices from the
connectors that are used.
3.
Place the batteries flat in the unit and close it.
4.
Turn off the switch, and check the battery voltage directly on the connector at the rear of the unit.
4.3.3.4.2 Preparing an External Battery Unit (stack Version)
Before starting the installation, note that:
• External batteries must be of the same type, must be supplied by the same manufacturer and be
from the same batch run.
• Batteries must be charged prior to installation.
Chapter
4
Powering and connecting the PBX to the customer LAN
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
56/216