8.1.2.1.6 Upgrading the software
The Alcatel-Lucent OmniTouch
™
8082 My IC Phone set software is upgraded during OXO Connect
software upgrade. Ensure the
8082 My IC Phone
option is validated in the
OMC-Software Download
window: refer to the section
Downloading the Software
in document [11].
8.1.2.2 Reset to factory
8.1.2.2.1 Overview
The reset to factory is intended to cope with situations in which the administrator can no longer access
the set configuration because the set administrator password has been lost, and the set is configured
in static mode or uses a specific VLAN on the previous installation. Reset to factory is not needed
when a set is configured in dynamic mode: in this case, the set administrator password can be
changed through the device management tool.
The reset to factory enables to restore the set to the “Out of the box” initial status, except that the
software version remains unchanged on the set. It works during the set initialization. If initialization is
done, there is no other solution to reset sets to their factory settings.
The reset to factory performs the following actions:
• Restore the set administrator password to its default value
• Clean all user data and webapps
• Restore the configuration and settings to their default values
• Remove certificate data such as customer certificates and CTL, except ALE International default
certificate stored during manufacturing
• Store a message into Defense log to indicate a reset-to-factory has been done
• Reboot
Note:
Although the feature is not intended for end-users, it is available in user mode, as this feature is used when the set
administrator password has been lost, and therefore the administrator mode cannot be reached.
It is not possible to limit the availability of the feature for users and/or administrators by setting the appropriate
display-rights to the setting
EnableResetFactory
in the third configuration files, generated by the
Customizer.
8.1.2.2.2 Procedure
To perform the reset to factory on a set:
1.
Restart the set
2.
During set initialization (step 2 or 3), press
Settings
3.
Select
Device
>
Reset
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
122/216