Note:
Due to hardware, there is a limit in the number of channels that you can configure.
You can configure the following numbers of channels:
•
DECT EUROPE, LATAM, CHINA: 1, 2, 4, 5, 8, 10 channels
•
DECT US: 1, 2, 4, 5 channels
•
PWT: 1, 2, 4, 5, 8 channels
8.10.1.9 Initialization
Once the IBS finishes the downloading, the system starts the initialization.
The system synchronizes the signals of the IBSs so that handovers are possible. The system selects
the T0, T2, or CPU main board clock as the source.
Then the system sends the following data:
• Fixed part capabilities (Full slot, frequency control, page repetition, setup on dummy, basic A field
setup): value sent = 0x007910
• Line length: Short line
• Frequency plan (2 bytes)
Some countries have shifted DECT frequencies. In order to be compatible with all frequency bands in
the different countries, 4 types of initialization of frequency plans are available:
Europe, Latin America, The United-States and China.
table 8.5: RF Band Europe
Channel
TX Freq
RX Freq
0
1897.344
1898.206
1
1895.616
1896.480
2
1893.888
1894.752
3
1892.160
1893.024
4
1890.432
1891.296
5
1888.704
1889.566
6
1886.978
1887.840
7
1885.248
1886.112
8
1883.520
1884.384
9
1881.792
1882.656
Note:
By default, all frequencies used
Value sent to IBS: 0x3FF
0000 0011 1111 1111
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
161/216