![Nokia Alcatel-Lucent OXO Connect Compact Installation Manual Download Page 144](http://html.mh-extra.com/html/nokia/alcatel-lucent-oxo-connect-compact/alcatel-lucent-oxo-connect-compact_installation-manual_255140144.webp)
1
2
3
V24/CTI PC
V24/CTI
Interface Module
Wall Socket
(to the PCX)
UA line
or
CTI
V24
9 Series Set
(Optional)
UA line
Figure 8.8: V24/CTI Interface Module Connection
The V24/CTI Interface Module is connected to:
1.
The digital set 3 m maximum length ( RJ11/RJ11 cable)
2.
The PCX via a wall socket and a distributor frame
3.
The CTI or V24 terminal:
• V24: 3m maximum length
• CTI: 3m maximum length
8.7.3.2 V24/CTI Interface Module Rear Panel Details
UA
1
2
3
Figure 8.9: Rear Panel
1.
RJ11 connector for UA line to PCX
2.
V24 SUBD9 connector
3.
CTI SUBD9 connector