![Nokia Alcatel-Lucent OXO Connect Compact Installation Manual Download Page 119](http://html.mh-extra.com/html/nokia/alcatel-lucent-oxo-connect-compact/alcatel-lucent-oxo-connect-compact_installation-manual_255140119.webp)
SIP registration OK
SIP phone connected and successfully regis-
tered to OXO Connect
8.1.2.1.2.10 Terminal conference
8082 My IC Phone sets can handle their own local conference, involving up to 2 external members. In
this case, conference is not handled at call server level and the
Conference
parameter configured in
System Miscellaneous
>
Feature Design
>
Part 3
does not apply.
8.1.2.1.3 Ringing parameters
The set user can select different ringing tones for the different types of call or event.
To configure ringing tones:
1.
Touch the
Settings
button
Note:
According to system administration, this button may not appear. The availability of this option is determined by
the set configuration files. Contact your telephony and/or system administrator.
2.
Select
Devices
>
Audio
3.
Review/modify the following parameters:
On-site ringing
Select the ringing for external calls
Off-site ringing
Select the ringing for internal calls
Event ringing
Select the ringing for calendar events
Special ringing
Select the ringing indicating that the Bluetooth
®
handset is out of range
8.1.2.1.4 Video call parameters
The OmniPCX Management Console (OMC) is used to enable the video call support for the 8082 My
IC Phone sets. Once configured it is possible to make:
• Basic P2P video calls between 8082 My IC Phone (VHE-2) and any SIP phone with video support.
• Basic video calls from 8082 My IC Phone (VHE-2) over a SIP trunk
The configuration for video is carried out in two steps:
1.
Generic SIP phone parameters for video calls are verified and modified if necessary, see
2.
Enabling video support for a 8082 My IC Phone set
8.1.2.1.4.1 Generic video parameters
The parameters in the table are generic (common) to all 8082 My IC Phone sets. They are accessed
from OMC:
• As of OXO Connect R2.1:
Subscribers Misc
>
Generic Parameters for SIP Phones
>
Video Call parameters
• As of OXO Connect R3.0:
System Miscellaneous
>
Generic Parameters for IP Phones
>
Video Call parameters
Video Camera Country Frequency
: defines the vertical scan frequency which is needed to avoid
flickering of video. This is same as the mains power frequency of the country. Default value for this
parameter is kept based on the target type (country) of the OXO Connect.
Chapter
8
Device commissioning
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
119/216