19
EN
Function settings list
CAUTION
z
z
Always record the set values. You can utilize “Setting memo” (p. 70).
If the tool fails, all settings may be initialized. Also, settings may be initialized at the time of repair in order to
check operation.
Please note that there is no function to output the set values to an outside device.
In screw fastening mode, press and hold the [MEMORY] button and [SELECT] button to enter the function setting
mode. For the operation procedure, see “11 Setting Functions” (p. 34).
The following settings are available.
No.
Function
Set values and operation
Default Reference
1
Workpiece signal
0: Do not input / 1: Input
0
p. 49
2
Workpiece setup time
0 sec.: OFF / 0.1- 9.9 sec.: 0.1 sec. intervals
0
p. 51
3
Start timing of workpiece setup NG
0: When workpiece is set / 1: When workpiece
is set and the screwdriver rotates
0
p. 51
4
Screw fastening confirmation time
0 sec.: OFF / 0.1- 9.9 sec.: 0.1 sec. intervals
0
p. 35
5
OK signal output timing
0: When the set count ends / 1: When the set
count ends and the workpiece is removed
0
p. 52
6
NG signal output time
0 sec.: OFF / 0.1- 9.9 sec.: 0.1 sec. intervals
0.1
p. 36
7
NG display
0: Do not continue / 1: Continue
0
p. 36
8
NG signal output selection
0: Output all NGs / 1: Output screwdriver NG /
2: Output workpiece setup NG
0
p. 54
9
Count return function
0: Do not use / 1: Use
0
p. 39
10
Count method
0: Count down / 1: Count up
0
p. 40
11
Bit Breaks function
0: Do not use / 1: Use
0
p. 40
12
Channel switching method
0: Inside screwdriver / 1: External signal
0
p. 60
13
Pin No. 7 output switching
0: Outputs channel switching signal / 1: LINK-
OUT
0
p. 57
14
Pin No. 4 input switching
0: Forced stop signal / 1: LINK-IN
0
p. 57
15
Screw fastening completion sound setting
0: OFF / 1: Sounds beep for each screw
1
16
OK sound setting
0: OFF / 1: Pi Pi Pi / 2: Pin Pon / 3: Do Re Mi /
4: Pi Po / 5: Pi-Pi Pi--
1
17
Workpiece setup NG sound setting
0: OFF / 1: Bu Bu Bu / 2: Bu-Bi-- / 3: Do Si La /
4: Bu-- / 5: Bu-Bu Bu--
(Only NG display E7 for No. 17, NG sound
other than E7 for No. 18)
1
18
Screwdriver NG sound setting
1
Time display
0.01 sec. increments
0.01 sec.
0.02 sec.
0.99 sec.
0.1 sec. increments
1.0 sec.
1.1 sec.
9.9 sec.
TV07521-1_DLV30S12P-AYK_en.indb 19
2017/02/10 15:56:32