18
EN
7 Basic Settings
Operation mode
The tool can be set to handle various screw tightening.
You can enter each mode from the screw fastening mode.
For details on operation and the operation of each function, see the reference page.
Mode
Operation
Operation to return to screw fastening mode Reference
Change channel
Press and hold the [UP] button
Press and hold the [MEMORY] button or
[SELECT] button
p. 22
Check set values
The changeover switch in n
Start switch ON
Start switch OFF
p. 23
Motion setting mode
Press and hold the [MEMORY] button
+ [UP] button
Press and hold the [MEMORY] button or
[SELECT] button
p. 24
Function setting mode
Press and hold the [MEMORY] button
+ [SELECT] button
Press and hold the [MEMORY] button or
[SELECT] button
p. 34
Lock/unlock keys
Press and hold the [MEMORY] button
Return automatically
p. 41
Screw count reset
Press and hold the [SELECT] button
Return automatically
p. 38
Count return mode
The changeover switch at the reverse
side + press and hold the [DOWN]
button
Return automatically, or press and hold
the [SELECT] button, or operate the
changeover switch
p. 39
Data receiving mode
Press and hold the [MEMORY] button
+ [DOWN] button.
Return automatically, or press and hold
the [SELECT] button
p. 43
Motion settings list
CAUTION
z
z
Always record the set values. You can utilize “Setting memo” (p. 70).
If the tool fails, all settings may be initialized. Also, settings may be initialized at the time of repair in order to
check operation.
Please note that there is no function to output the set values to an outside device.
In screw fastening mode, press and hold the [MEMORY] button and [UP] button to enter the motion setting mode. For
the operation procedure, see “9 Motion Setting” (p. 24).
The following settings are available.
No.
Function
Set values and operation
Default
1
Screw count
1 - 99 screws
1
2
Speed level at start
Level 1 - 9
(Parameter LED display is L1, L2...L9)
L9
3
Rotation time at start
0 sec.: 1st stage rotation setting is OFF / 0.01 - 0.99 sec.: 0.01
sec. intervals / 1.0 - 9.9 sec.: 0.1 sec. intervals
0
4
Speed level at middle
Level 1 - 9
(Parameter LED display is L1, L2...L9)
L9
5
Rotation time at middle
0 sec.: 2nd stage rotation setting is OFF / 0.01 - 0.99 sec.: 0.01
sec. intervals / 1.0 - 9.9 sec.: 0.1 sec. intervals
0
6
Speed level at finish
Level 1 - 9
(Parameter LED display is L1, L2...L9)
L9
7
Lower limit of screw fastening time
0 sec.: Lower limit of screw fastening time is OFF / 0.01 - 0.99
sec.: 0.01 sec. intervals / 1.0 - 9.9 sec.: 0.1 sec. intervals
0
8
Upper limit of screw fastening time
0 sec.: Upper limit of screw fastening time is OFF / 0.01 - 0.99
sec.: 0.01 sec. intervals / 1.0 - 9.9 sec.: 0.1 sec. intervals
0
9
Auto reverse mode setting
0: OFF / 1: Reversal after torque-up / 2: Reversal after lower
limit of screw fastening time
0
10
Reverse speed level
Level 1 - 9
(Parameter LED display is L1, L2...L9)
L9
11
Reverse rotation time
0 sec.: Reverse setting is OFF / 0.1 - 0.99 sec.: 0.01 sec.
intervals / 1.0 - 9.9 sec.: 0.1 sec. intervals
0
TV07521-1_DLV30S12P-AYK_en.indb 18