36
EN
Adjusting the NG signal output time
You can check the NG content by setting the NG signal output time. When resuming work after NG work, if you have
set the NG display to continue, you can understand that the work is interrupted by NG work.
When NG operation occurs, the parameter LED displays a No. from E1 to E9 and the main LED lights in red. During
NG signal output time, the electric screwdriver does not operate.
By setting the NG display to “1: Continue”, the parameter LED keeps displaying a value between E1 and E9. The main
LED goes off. At this point, if you press the [UP] button, the mode changes to screw fastening mode.
* Only with E7, regardless of the set value, the NG signal is output until the workpiece signal is input again.
1
In screw fastening mode, press and hold the [MEMORY] button and [SELECT] button
The mode enters function setting mode.
2
Press the [SELECT] button to select function No. 6
3
Use the [UP] button or [DOWN] button to change the NG signal output time (0.1 - 9.9 sec.)
4
Press the [SELECT] button to select function No. 7
5
Use the [UP] button or [DOWN] button to change the NG display
6
Press and hold the [MEMORY] button to save the setting
TV07521-1_DLV30S12P-AYK_en.indb 36