48
EN
Timing of I/O signal
Input signal
Signal timing
Remarks
Workpiece signal
ON
OFF
While the input signal is ON, the workpiece signal is
ON
Reset signal
ON
OFF
When the input signal is ON for 0.5 sec., reset is ON
LINK-IN
ON
OFF
Input from final screwdriver (see “Link function”
(p. 55))
Forced stop signal
ON
OFF
While the input signal is ON, forced stop signal is ON
Channel A/B/C
ON
OFF
While the input signal is ON, channel A/B/C is ON
Output signal
Signal timing
Remarks
OK signal
ON
OFF
When the OK signal is output, ON for 0.1 sec.
Or ON until the workpiece is removed
(See “Adjusting the OK signal output” (p. 52))
NG signal
ON
OFF
ON during the NG signal output time
(See “Selecting the NG signal output” (p. 54))
E7 is ON until the workpiece signal is input again
LINK-OUT
ON
OFF
Output for all screwdriver before the final screwdriver
(see “Link function” (p. 55))
TV07521-1_DLV30S12P-AYK_en.indb 48
2017/02/10 15:56:37