English
7
– English
a)
– insert the square pivot into the support (
fig. 19-A
);
b)
– thread the metal pin into the square pivot and bend one end so
that it does not unthread (
fig. 19-B
);
c)
– finally, at the other end of the tube, slide the roller into the sup
-
port interior (
fig. 19-C
).
16.
Carefully position and affix the power cable to the inside of the case,
in its final position.
Warning
– the power cable must be positioned
far away from moving parts (
fig. 20
).
17.
Thread the three attachment springs (supplied) into the free groove of
the first slat (at the top) of the roller shutter (
fig. 21
) and position them
as follows: measure the carriage length, divide this measurement in
-
to 6 equal parts and position the springs at around 1/6th, 3/6ths et
5/6ths of the length of the carriage (
fig. 22
).
18.
Then affix the three springs to the tube as illustrated in
fig. 23
.
PHASE 5
5.1 - CONNECTING THE AUTOMATION SYSTEM TO
THE ELECTRICAL GRID
CAUTION! – Connection operations described in this phase
must be carried out by a qualified electrician, whilst observing
these instructions and the safety standards in force in the coun-
try of installation.
CAUTION!
• Incorrect connection can cause faults or dangerous situations, therefore
scrupulously respect the instructions given in this paragraph.
• If the power supply cable is damaged, the product cannot be used be
-
cause the cable cannot be replaced. In these cases, contact the After-
sales Ser vice
.
Connect the automation system to the mains using a power cable made
up of three conductors:
19 A
19 C
1
2
19 B
20
–
brown wire
, for connection to “Phase”
–
blue wire
, for connection to “Neutral”
–
yellow-green wire
, for connection to “Earth”
5.1.1 - Installation of protection devices within the electric
network
In compliance with the electric installation rules, in the network that pow
-
ers the motor, a
short circuit protection device and a disconnection de-
vice from the mains electricity
must be envisioned.
Attention! – The disconnection device must allow the complete
disconnection of the power supply, in the conditions established
by the over-voltage category III.
The disconnection device must be located in view of the automation and,
if it is not visible, must envision a system that blocks any accidental or
unauthorised re-connection of the power supply, in order to prevent any
danger.
Note
– The two devices are not present in the package.
PHASE 6
6.1 - FIRST COMMISSIONING AND ELECTRICAL
CONNECTIONS CHECKS
When the electrical connections are complete, before continuing, you
must immediately check that the connections have been carried out cor
-
rectly, and therefore that the installation works.
To do this, carry out the following operations:
01.
Switch on the automation system.
02.
At the same time, check whether the motor makes 2 short move
-
ments (the direction of rotation is not important):
the 2 short move
-
ments confirms that the automation system is properly connected
.