Output
Switch
+
-
Common
Load
Output
SINKING
OUTPUT
T-DAR IO
T-DAR Digital Outputs
The T-DAR uses relays for outputs. When the relay is triggered, connection points A
& B are closed and current is allowed to pass. Applications should not exceed 3
amps.
The following diagram illustrates the typical installation for the sinking type of output:
Figure 39- Sinking Outputs