75
All Monitored Events Are Failing
If a working installation suddenly returns failed inspections for all or most of the
inspections, the T-DAR Stereo Camera Head has probably been bumped, or
something has obscured the field of view. A change in lighting conditions is another
possible problem area. Observe the video output results to help determine causes
of failure.
♦
Check the lighting
conditions
A light source that dims over time or a light source that has
gone out completely can affect the performance. Make
sure that your light sources are strong and positioned
correctly. Good lighting is essential to getting a good
image and to security monitoring performance. To see the
effect of the lighting, select an output that best displays the
problem and monitor the live image.
♦
Check to see if the
Stereo Camera
Head is out of
position
Put the Camera Head to its original position. If you are
unsure, reposition it as close to the original location as
possible.
If you cannot reposition the unit properly, connect the
Control Unit to the host computer and redo setup in the
User Interface
Summary of Contents for T-DAR T1000