![Newton Security T-DAR T1000 Installation And Operation Manual Download Page 51](http://html1.mh-extra.com/html/newton-security/t-dar-t1000/t-dar-t1000_installation-and-operation-manual_1680906051.webp)
51
Initial Set-up
The initial Set-up tab is the most important tab in the UI. Here the technician will
enter the camera height, Distance to floor, orientation of cameras, load camera
calibrations, and the most important element draw the Green line (line of
demarcation) for automatically setting up the users regions. Here the serial number
and IP address of the unit will also be found. Until all of the fields are properly filled
out on this tab you will not be able to move to any other tabs in the UI to complete
the installation.
Figure 23 - Initial Set-Up Tab
Camera set-up
Here the technician will input various distances that the cameras are place away
from the door and the floor. Also you choose the orientation of your cameras and
load the calibration files. (
See stereo head placement chart for optimal placement
)
Video modes
Here the installer picks between NTSC and PAL depending on the type of camera
and video system they are using
Green Line
With the crosshair draw a green line at the base of the door, which the unit is
installed (as shown). This will automatically set-up the regions for scanning.
Summary of Contents for T-DAR T1000
Page 12: ...12 Figure 2 T DAR Control Unit CAD...
Page 14: ...14 Figure 4 T DAR Annunciator CAD...
Page 16: ...16 Figure 6 T DAR Stereo Tracking Head...
Page 18: ...18 F igure 8 T DAR Door Encoder...
Page 20: ...20 Figure 10 T DAR Event Camera...
Page 22: ...22 Figure 12 T DAR Cable Extender Amplifier CAD...
Page 37: ...37 Figure 16 Typical Dry Configuration...
Page 89: ...89...