![Newton Security T-DAR T1000 Installation And Operation Manual Download Page 84](http://html1.mh-extra.com/html/newton-security/t-dar-t1000/t-dar-t1000_installation-and-operation-manual_1680906084.webp)
84
T-DAR Dual Digital Inputs
The T-DAR uses dual polarity opto-isolators on all digital inputs. All inputs
can be used as either sinking or sourcing inputs.
Note: as there is a single common for the entire set of inputs, all inputs must
be configured as either sourcing or sinking.
It is not possible to mix the inputs between sourcing and sinking
.
The following diagrams illustrate the typical installation for each of the types
of input:
Figure 38 - Sourcing/Sinking Inputs
Input
Sensing
+
-
Common
Input
SOURCING
INPUT
T-
DAR IO
Input
Sensing
+
-
Common
Input
SINKING
INPUT
T-
DAR IO