DC200LP Stereo Tracking Head
Figure 5 - T-DAR Stereo Tracking Head
Size
: 7.00” x 2.50” x 2.50”
Weight
: 2.2 lbs.
Enclosure
: Bent steel.
Mounting
: Mounting via 4 x 1/8" holes on back panel tabs. (Optional mounting
brackets available)
Standard Operating Temperature:
40 to 125 degrees F, (optional high and low
temperature systems available)
Storage Temperature:
0 to 150 degrees F
Input Voltage/Current
12VDC 1A maximum (Powered by the
CB100/200 Control Unit)
Inputs
1-RJ45 Std. Ethernet from Control Unit
Outputs
NTSC or PAL Stereo Video (Specify)
Video Connectors
BNC x2 (RG-59U)
Focus and Field of View
Factory fixed, non-adjustable
(Correct part number must be specified
for the application camera height.
Consult the table on Page 38 for the lens
specification and part number)
Lighting
Both Visible and Near IR (Invisible to
human eyes) DC200 camera heads are
available